Glossary: rope and mooring terms explained
The key terms around rope, strength and mooring explained in plain language: from MBL and LDBF to creep, D/d and snap-back.
- Breaking load (BL)
- The force at which a rope breaks under straight tension, given in kN or tonnes.
- MBL (minimum breaking load)
- The guaranteed minimum breaking load of a new, dry rope. Selection and working load are based on this figure.
- Spliced breaking load / LDBF
- Line Design Break Force: the breaking load of the rope with spliced eyes, tested as it is used on board. For 12-strand rope usually about 10% lower than the MBL of the rope itself.
- Ship design MBL (MBLSD)
- The minimum breaking load for which a vessel’s bollards, fairleads, winches and hull structure are designed. New mooring lines should have an LDBF of 100–105% of this value.
- TDBF
- Tail Design Break Force: the breaking load of a tail including splices, as stated by the manufacturer.
- Working load (WLL / SWL)
- The maximum load a rope or fitting may see in normal use. For mooring lines, a rule of thumb is a working load of no more than half the LDBF, and for a long service life a normal operating load of around 20–25% of the MBL.
- Safety factor
- The ratio between breaking load and working load. See the rope calculator for common values per application.
- Elongation
- How much a rope lengthens under load, in percent. Elongation at break is the stretch at the moment of failure.
- Modulus
- The stiffness of a fibre or rope: the higher the modulus, the less it stretches under the same load. HMPE has a very high modulus.
- Creep
- Slow, permanent lengthening of a rope under constant load. Mainly relevant for HMPE under long-term load.
- Fatigue
- Weakening caused by repeated loading and unloading, or by bending over rollers and bollards. Often caused by internal abrasion.
- Shock load
- A sudden, rapid rise in load, for example from swell or a passing ship. A rope visibly damaged by a shock load must be retired immediately.
- D/d ratio
- The diameter of the roller, bollard or fairlead (D) divided by the rope diameter (d). The smaller D/d, the more strength the rope loses through bending.
- Geometric factor
- Factor used to calculate the load on a fitting from the line tension and the angle the rope wraps around it.
- Snap-back
- The dangerous recoil of a rope that breaks under tension. Elastic ropes recoil with more energy; always stay out of the snap-back zone.
- Tail
- A short, elastic length of rope at the end of a mooring line. The tail absorbs shock loads, takes most of the wear and is cheap to replace.
- Mixed mooring
- Using mooring lines with very different stretch side by side in the same direction. Not recommended: the stiffest line then takes almost all the load.
- dtex
- Measure of fibre or yarn thickness: the weight in grams per 10,000 metres.
- HT and HM
- High tenacity (polyester, polyamide, polyolefin) and high modulus (HMPE, aramid). See fibres and materials.
- Qualified person
- Someone qualified by training, certificate or proven experience to inspect mooring lines and decide on retirement.
- Certificate 2.2, 3.1, 3.2
- Certificate types under EN 10204: 2.2 confirms the rope meets the order, 3.1 shows break tests on the production batch, and for 3.2 an independent inspection body witnesses the test.